Application: Connection of domestic appliances (built-in and freestanding cooktops) that use natural gas, manufactured gas, or LPG.
Test: Helium leak detector (spectrometer) with a test value of 1×10 mbar·l/s.
Fittings: Supplied with female/female or female/male connections in the following lengths: 500, 750, 1000, 1250, 1500, and 2000 mm.
Operating pressure: Limited to 0.5 bar in accordance with current regulations, which permit its use on appliances with a nominal thermal output not exceeding 35 kW.
Operating temperature range: –40 °C to +60 °C.
Minimum bending radius: 1.5 times the outer diameter of the tube.
Tube: Continuous-wall corrugated type, fittings and braiding are made of austenitic stainless steel.
Cover: Plastic material outer sheath.
| Code | DN | Length | Size |
| mm | |||
| KL 980182 | 12 | 500 | F1/2"-F1/2" |
| KL 980183 | 12 | 750 | F1/2"-F1/2" |
| KL 980184 | 12 | 1000 | F1/2"-F1/2" |
| KL 980185 | 12 | 1250 | F1/2"-F1/2" |
| KL 980186 | 12 | 1500 | F1/2"-F1/2" |
| KL 980187 | 12 | 2000 | F1/2"-F1/2" |